Wireless Monitoring System
WiSenMeshWAN 6F07/6F08 Omni Tilt Distance Node
This internally powered sensor node allows measurement of tilt from the horizontal plane. With a full tilt range (360°any axis) and very high accuracy (±0.002°)and
resolution (±0.0001°). The omni-axis sensors can be installed in any orientation and automatically detect the horizontal plane. The nodes also include an integrated temperature sensor and wireless mesh radio transmitter via the external antenna. The battery lifespan is up to 15 years at hourly readings. It is also available in a configuration designed specifically for rail track monitoring with an integrated internal antenna.

Long term distance monitoring between two specific points, such as horizontal convergence of a tunnel.
Basics |
||
Battery Power |
Qty. x 1 (3.6V Lithium primary D-Cell ER34615) |
|
Accuracy Stop Voltage |
2.7VDC |
|
Mesh Stop Voltage |
2.1VDC |
|
Battery Connection |
Standard Aluminium Battery Holder |
|
Working Current (DC) |
Max. 65mA (Typ. 50mA) |
|
Local Storage |
Min. 450 Messages during Meshing |
|
L x W x H |
80 x 75 x 57mm |
|
Weight |
0.43kg |
|
Primary Sensor |
||
Sensor Type |
X-axis; Y-axis; Z-axis Tilt Values |
|
Range |
-90° to +90° |
|
Accuracy |
0.002° (7.2’’ or 0.0349mm/m) @ [-2.0°, 2.0°] & Better than 0.01° (36’’ or 0.1745mm/m) @ Any 1° over (-90°, 90°) |
|
Resolution |
0.0001° (0.36″ or 0.001745mm/m) |
|
Standard System Parameter |
||
Temperature |
Range: -40 to 85°C; Accuracy: ±1°C, typical 0.5°C; Resolution: 0.1°C |
|
Voltage |
Accuracy: ± 0.1V |
|
WSN Interface |
||
Mesh Wireless Interface |
WiSenMeshWAN® Protocol |
|
Industrial Standard |
||
Casing and Painting Materials |
Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating) |
|
IP Rating |
≥ IP66 |
|
Operating Temperature |
-40 to 85°C |
|
Fire Proof |
Approved |
|
Certificates |
FCC, ACMA |
|
Re-Calibration Method |
||
Inspection Period |
Every 3 Years by Manufacturer (or inspected by arranged methods) |
|
Tilting Orientation |
||
1) When holding the Spec paper horizontally, then when X-axis arrow rotates around 0-dot into the paper plane, the readings of “x” decreases; It also applies to both Y/Z-axis; 2) The node fixings must be rigid for the sensor to measure accurate data. Movement in the fixings will affect the readings; 3) The Omni Tilt Sensor Nodes must be oriented with any two axis marked on the label parallel to the horizontal plane, so that the data can be easily interpreted. |
||
Applications |
||
Infrastructure tilting condition monitoring, such as retaining wall, supporting column, river embankment etc. From the 1st level of data conversion, the movement of one end of a beam/crossbar can be monitored, such as land sliding, railway track monitoring. With our latest developed mathematical model, we can achieve the Horizontal Convergence of a metro tunnel of 6 segments. |
||
Installation Guidance: The tilt node could be installed in any position. |
||
Figure. Standard Omni Tilt Sensor Node Product Photos (Subject to the final product). |
WiSenMeshWAN 6F07/6F08 Omni Tilt Distance Node
WiSenMeshWAN® Product @ 915, 868, 433MHz Radio Frequency
Casing and Painting Materials: | Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating) |
IP Rating: | >= IP66 |
Operating Temperature: | -10 to 50°C |
Fire Proof: | Approved |
Certificates: | CE, FCC, ACMA, RoHS, REACH |
-
Omni-axis tilt 360° range
-
±0.002° accuracy
-
±0.0002° precision
-
±0.0001° resolution
-
Distance measurement 0.05m ~ 300m
-
Distance resolution ±0.1mm
-
Intelligent node/repeater
-
Battery life up to 6 years
-
1 second to 1 hour variable readings
-
End user configurable
-
Rugged Housing
-
IP66
-
Gravity Orientation Sensor