Wireless Monitoring System

WiSenMeshWAN 6F07/6F08 Omni Tilt Distance Node

This internally powered sensor node allows measurement of tilt from the horizontal plane. With a full tilt range (360°any axis) and very high accuracy (±0.002°)and
resolution (±0.0001°). The omni-axis sensors can be installed in any orientation and automatically detect the horizontal plane. The nodes also include an integrated temperature sensor and wireless mesh radio transmitter via the external antenna. The battery lifespan is up to 15 years at hourly readings. It is also available in a configuration designed specifically for rail track monitoring with an integrated internal antenna.

Omni Tilt & Distance Node

Long term distance monitoring between two specific points, such as horizontal convergence of a tunnel.

6305 Type – WiSenMeshWAN® Omni Tilt Sensor Node

Basics

Battery Power

Qty. x 1 (3.6V Lithium primary D-Cell ER34615)

Accuracy Stop Voltage

2.7VDC

Mesh Stop Voltage

2.1VDC

Battery Connection

Standard Aluminium Battery Holder

Working Current (DC)

Max. 65mA (Typ. 50mA)

Local Storage

Min. 450 Messages during Meshing

L x W x H

80 x 75 x 57mm

Weight

0.43kg

Primary Sensor

Sensor Type

X-axis; Y-axis; Z-axis Tilt Values

Range

-90° to +90°

Accuracy

0.002° (7.2’’ or 0.0349mm/m) @ [-2.0°, 2.0°] & Better than 0.01° (36’’ or 0.1745mm/m) @ Any 1° over (-90°, 90°)

Resolution

0.0001° (0.36″ or 0.001745mm/m)

Standard System Parameter

Temperature

Range: -40 to 85°C; Accuracy: ±1°C, typical 0.5°C; Resolution: 0.1°C

Voltage

Accuracy: ± 0.1V

WSN Interface

Mesh Wireless Interface

WiSenMeshWAN® Protocol

Industrial Standard

Casing and Painting Materials

Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating)

IP Rating

≥ IP66

Operating Temperature

-40 to 85°C

Fire Proof

Approved

Certificates

FCC, ACMA

Re-Calibration Method

Inspection Period

Every 3 Years by Manufacturer (or inspected by arranged methods)

Tilting Orientation

1)       When holding the Spec paper horizontally, then when X-axis arrow rotates around 0-dot into the paper plane, the readings of “x” decreases; It also applies to both Y/Z-axis;

2)       The node fixings must be rigid for the sensor to measure accurate data. Movement in the fixings will affect the readings;

3)       The Omni Tilt Sensor Nodes must be oriented with any two axis marked on the label parallel to the horizontal plane, so that the data can be easily interpreted.

Applications

Infrastructure tilting condition monitoring, such as retaining wall, supporting column, river embankment etc.

From the 1st level of data conversion, the movement of one end of a beam/crossbar can be monitored, such as land sliding, railway track monitoring.

With our latest developed mathematical model, we can achieve the Horizontal Convergence of a metro tunnel of 6 segments.

Installation Guidance: The tilt node could be installed in any position.

Figure. Standard Omni Tilt Sensor Node Product Photos (Subject to the final product).

WiSenMeshWAN 6F07/6F08 Omni Tilt Distance Node

WiSenMeshWAN® Product @ 915, 868, 433MHz Radio Frequency

Casing and Painting Materials:  Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating)
IP Rating:  >= IP66
Operating Temperature:  -10 to 50°C
Fire Proof:  Approved
Certificates:  CE, FCC, ACMA, RoHS, REACH
  • Omni-axis tilt 360° range

  • ±0.002° accuracy

  • ±0.0002° precision

  • ±0.0001° resolution

  • Distance measurement 0.05m ~ 300m

  • Distance resolution ±0.1mm

  • Intelligent node/repeater

  • Battery life up to 6 years

  • 1 second to 1 hour variable readings

  • End user configurable

  • Rugged Housing

  • IP66

  • Gravity Orientation Sensor

Want To Know More?

Get in touch and one of our experts will get back to you.